Outdoor AC Disconnector H.V. GW4 Two-Column Disconnector 40,5-252kV
Application: In rated voltage 40.5~252kV power system, to separating the circuits under off-load status, set up air electrical clearning between the tested electrical apparatuses and electrified circuit.
Standards: IEC 62271-102
Parameters: Rated voltage: 40.5-252kV.
Rated current: 1250-4000A.
Rated short time withstand current, 3s: 50kA.
Features:
- Outstanding performances and reliable operation.
- Free maintenance due to its stable contact pressure and self-cleaning capability.
- High anticorrosion capability.
- Easy installation and adjustment.
GW22 Vertical Single-Column & Single-arm Flexible Fold Type Disconnector 252kV
Application: In 252kV power system, to separating the circuits under off-load status, set up air electrical clearning between the tested electrical apparatuses and electrified circuit.
Standards: IEC 62271-102
Parameters: Rated voltage: 252kV.
Rated current: 3150, 4000A.
Rated short time withstand current, 3s: 50kA.
Features:
- With the min. phase distance and vertical length compared with similar products.
- With high mechanical intensity and light by adoption of aluminum alloy at the conductive part.
- Reliable operation.
- Influence of the environment reduced with the operation mechanism and balancing spring sealed in tubes
GW23 Horizontal Single-arm Flexible Fold Type Disconnector 252kV
Application: In 252kV power system, to separating the circuits under off-load status, set up security air electrical clearning between the tested electrical apparatuses and electrified circuit.
Standards: IEC 62271-102
Parameters: Rated voltage: 252kV.
Rated current: 3150A.
Rated short time withstand current, 3s: 50kA.
Features:
- With the min. phase distance and vertical length compared with similar products.
- With high mechanical intensity and light by adoption of aluminum alloy at the conductive part.
- Reliable operation.
- Influence of the environment reduced with the operation mechanism and balancing spring sealed in tubes.
- Increased contact range of moving and static contact.
- Most of the components could be used on GW22-252 disconnector.
HV Earthing switch 126, 252kV
Application: In 126-252kV power systems for HV busbars.
Standards: IEC 62271-102
Parameters: Rated voltage: 126kV, 252kV.
Rated short time withstand current, 3s: 40kA, 50kA.
Rated lighting impulse withstand voltage: 550kV, 1050kV.
Features:
- Compact design, stale performances and reliable contact.
- Good anticorrosion performances of the base.
- Easy installation and adjustment.